A test method is the documented procedure used to obtain a result. A number on a report should be read with the method that produced it.

A documented procedure

A test method is the documented procedure used to obtain a result.

Read the number with the method

A number on a report should be read with the method that produced it.

The method can change the result

Changing the method can change the result, even for the same sample.

Not a use protocol

A method description documents how a test was done. It is not a protocol for using the material.

Identity and purity answer two different questions

Identity and purity answer two different questions. One test does not replace the other.

Identity

Is the main component consistent with the named compound?

Purity

Under a stated method, how much of the detected signal is the main peak?

Identity is one question

Identity asks whether the main component is consistent with the named compound. A mass match does not, by itself, state purity.

Purity is another question

Purity asks, under a stated method, how much of the detected signal is the main peak. An HPLC purity figure does not, by itself, confirm identity.

Complementary results

A mass match and an HPLC purity figure are complementary. One does not replace the other.

Two different tests

Mass spectrometry and HPLC answer different questions. The two results are complementary.

Mass spectrometry and HPLC

Mass spectrometry

Mass spectrometry (MS) is often used as an identity test: does the measured mass match the named compound?

HPLC

HPLC is often used as a purity test: under a stated method, how much of the detected signal is the main peak?

Mass is not purity

A mass match does not, by itself, state purity.

Purity is not identity

An HPLC purity figure does not, by itself, confirm identity.

What an HPLC purity percentage means

A purity figure should be read with the method. It is often reported from a chromatogram recorded under that method.

Signal Time

Peak-area percentage

It is often a peak-area percentage under that method.

Not, by itself, identity

It is not, by itself, a confirmation of identity.

Not a vial quantity

It does not, on its own, measure how much material is in a vial.

Read with the method

A purity figure should be read with the method that produced it.

How to read a chromatogram

A chromatogram is a plot of detector signal versus time as a sample moves through a column.

Peaks

Peaks are regions where the detector records a component.

Retention time

Retention time is when a peak appears under that method.

Purity figure

A purity figure, if reported, should be read with the method and with how peaks were integrated.

Laboratory data

A chromatogram is laboratory data. It is not, by itself, confirmation of identity or a measure of how much material is in a vial.

What a chromatogram baseline is

A baseline is the detector signal recorded when no peak is eluting. Peaks rise from the baseline and return to it, under a stated method.

Detector signal

A baseline is the detector signal recorded when no peak is eluting.

Peaks return

Peaks rise from the baseline and return to it, under a stated method.

Measured from baseline

A peak is often measured from that baseline.

Laboratory data

A baseline is laboratory data. It is not, by itself, a confirmation of identity or a measure of how much material is in a vial.

What a retention time is

Retention time is the time at which a peak appears on a chromatogram, under a stated method.

When a peak appears

Retention time is the time at which a peak appears on a chromatogram, under a stated method.

It depends on the method

It depends on the method, including the column and the mobile phase.

The method can change it

The same material can show a different retention time if the method changes.

Laboratory data

A retention time is laboratory data. It is not, by itself, a confirmation of identity, and it is not a use instruction.

HPLC columns and the mobile phase

Both the column and the mobile phase are part of the method and should be read with any HPLC result.

The column

In HPLC, the column is the tube packed with the material the sample travels through.

The mobile phase

The mobile phase is the liquid that carries the sample through the column.

Part of the method

Both are part of the method and should be read with any HPLC result.

Not a use instruction

A description of a column or mobile phase documents a test method. It is not a use instruction.

What “UV detection” means

UV detection means a detector measures how much ultraviolet light is absorbed as components leave a chromatographic column.

Absorbed ultraviolet light is recorded as a detector signal.

Ultraviolet absorption

UV detection means a detector measures how much ultraviolet light is absorbed as components leave a chromatographic column.

Many HPLC purity figures

Many HPLC purity figures are obtained with a UV detector, under a stated method and wavelength.

Not, by itself, identity

A UV signal is not, by itself, a confirmation of identity.

Read with the method

A UV-based purity figure should be read with the method.

What a mass spectrum peak is

A mass spectrum is a plot of detected signal against mass-to-charge ratio.

A peak marks a detected ion

A peak marks a detected ion at a recorded mass-to-charge value.

Compared in identity testing

In identity testing, a peak may be compared with the mass expected for the named compound.

Not a purity statement

A mass-spectrum peak is laboratory data. It does not, by itself, state purity.

Not a vial quantity

It does not, by itself, state how much material is in a vial.