A documented procedure
A test method is the documented procedure used to obtain a result.
Methods
A test method is the documented procedure used to obtain a result. A number on a report should be read with the method that produced it.
A test method is the documented procedure used to obtain a result.
A number on a report should be read with the method that produced it.
Changing the method can change the result, even for the same sample.
A method description documents how a test was done. It is not a protocol for using the material.
Identity and purity answer two different questions. One test does not replace the other.
Is the main component consistent with the named compound?
Under a stated method, how much of the detected signal is the main peak?
Identity asks whether the main component is consistent with the named compound. A mass match does not, by itself, state purity.
Purity asks, under a stated method, how much of the detected signal is the main peak. An HPLC purity figure does not, by itself, confirm identity.
A mass match and an HPLC purity figure are complementary. One does not replace the other.
Mass spectrometry and HPLC answer different questions. The two results are complementary.
Mass spectrometry (MS) is often used as an identity test: does the measured mass match the named compound?
HPLC is often used as a purity test: under a stated method, how much of the detected signal is the main peak?
A mass match does not, by itself, state purity.
An HPLC purity figure does not, by itself, confirm identity.
A purity figure should be read with the method. It is often reported from a chromatogram recorded under that method.
It is often a peak-area percentage under that method.
It is not, by itself, a confirmation of identity.
It does not, on its own, measure how much material is in a vial.
A purity figure should be read with the method that produced it.
A chromatogram is a plot of detector signal versus time as a sample moves through a column.
Peaks are regions where the detector records a component.
Retention time is when a peak appears under that method.
A purity figure, if reported, should be read with the method and with how peaks were integrated.
A chromatogram is laboratory data. It is not, by itself, confirmation of identity or a measure of how much material is in a vial.
A baseline is the detector signal recorded when no peak is eluting. Peaks rise from the baseline and return to it, under a stated method.
A baseline is the detector signal recorded when no peak is eluting.
Peaks rise from the baseline and return to it, under a stated method.
A peak is often measured from that baseline.
A baseline is laboratory data. It is not, by itself, a confirmation of identity or a measure of how much material is in a vial.
Retention time is the time at which a peak appears on a chromatogram, under a stated method.
Retention time is the time at which a peak appears on a chromatogram, under a stated method.
It depends on the method, including the column and the mobile phase.
The same material can show a different retention time if the method changes.
A retention time is laboratory data. It is not, by itself, a confirmation of identity, and it is not a use instruction.
Both the column and the mobile phase are part of the method and should be read with any HPLC result.
In HPLC, the column is the tube packed with the material the sample travels through.
The mobile phase is the liquid that carries the sample through the column.
Both are part of the method and should be read with any HPLC result.
A description of a column or mobile phase documents a test method. It is not a use instruction.
UV detection means a detector measures how much ultraviolet light is absorbed as components leave a chromatographic column.
Absorbed ultraviolet light is recorded as a detector signal.
UV detection means a detector measures how much ultraviolet light is absorbed as components leave a chromatographic column.
Many HPLC purity figures are obtained with a UV detector, under a stated method and wavelength.
A UV signal is not, by itself, a confirmation of identity.
A UV-based purity figure should be read with the method.
A mass spectrum is a plot of detected signal against mass-to-charge ratio.
A peak marks a detected ion at a recorded mass-to-charge value.
In identity testing, a peak may be compared with the mass expected for the named compound.
A mass-spectrum peak is laboratory data. It does not, by itself, state purity.
It does not, by itself, state how much material is in a vial.
For research use only. Not for human or veterinary use.
Educational content only. This site covers laboratory terms, methods, and how laboratory documents are read. It is not permission for any other use, and it is not a protocol for use.